Penrose, NC Heating & Cooling
Comfort Central is Penrose’s Top Choice for HVAC Solutions
Living in Penrose, we get the best of both worlds — warm southern summers and cool mountain winters. However, when the weather turns extreme, you want to be able to heat and cool your home so that you stay nice and comfortable.
Recent Jobs and Reviews in Penrose, NC
Our Local Reviews by City
- Alexander, NC (1)
- Arden, NC (7)
- Asheville, NC (76)
- Biltmore Forest, NC (1)
- Black Mountain, NC (6)
- Brevard, NC (65)
- Cedar Mountain, NC (2)
- Clyde, NC (1)
- Etowah, NC (11)
- Fairview, NC (7)
- Flat Rock, NC (10)
- Fletcher, NC (6)
- Hendersonville, NC (34)
- Horse Shoe, NC (2)
- Lake Junaluska, NC (1)
- Lake Toxaway, NC (5)
- Laurel Park, NC (4)
- Leicester, NC (2)
- Lower Hominy, NC (1)
- Maggie Valley, NC (3)
- Mills River, NC (4)
- Penrose, NC (9)
- Pisgah Forest, NC (29)
- Rosman, NC (3)
- Saluda, NC (1)
- Sapphire, NC (4)
- Waynesville, NC (4)
- Weaverville, NC (7)
- Woodfin, NC (3)
- Zirconia, NC (2)
Job Locations and Reviews
Review
Cameron S.
Performed AC maintenance tune up service on heat pump system checking both heat and cool due to late in season tune up. Checked all electrical components, refrigerant balance, units start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain line. Everything looks and runs great! No recommended changes at this time.
Penrose, NC 28766
Cameron S.
Customer concerned unit not making water due to potential issues with system. Checked system operation, checked drain pan, drain line pitch, system charge. Everything looks and runs great! Let system run long enough cycle for water to condense on evaporator coil and start to drip into pan and flushed drain line to check flow. Covered per Kevin's request.
Penrose, NC 28766
Kelsey T.
Performed tune up on system System is in great working condition. Indoor blower is pulling .9 amps Temperature difference between return and supply is 20 Outdoor compressor is pulling 4.7 amps Outdoor fan motor is pulling .5 amps Subcool is 6 Superheat is 8 Capacitor is within manufacturer specifications
Penrose, NC 28766
Jay E.
Replaced heat strip kit. Replaced air handler control board. Replaced coil sensor. Wrap the air handler to prevent any compensation. Didn’t tape the ends by the Plenum only taped where the two seam came together at the bottom of the front of the air handler. To access air handler just cut the tape on the bottom lift up the insulation Easy Peezy.
Penrose, NC 28766
Review
Cameron S.
Flushed and treated drain line and flushed and treated condensate pump to help prevent future back ups. Recommended customer keep an eye on it over the next couple of daysto insure system is draining still. Covered under warranty of previous call
Penrose, NC 28766
Cameron S.
Breaker burned up again. Recommend return with heat kit/breaker kit, blower board, evaporator coil sensor. Recommend wrapping unit with insulation to prevent excessive sweating inside the cabinet and outside.
Penrose, NC 28766
Review
Cameron S.
Furnish parts and labor to replace (2) Heating Elements, Sequencer, Transformer, Limits, wiring and wiring connectors.
Penrose, NC 28766
Cameron S.
Found indoor unit transformer, electric heat kit, and wiring harness has burned up, believed to be caused by failure of electric heat kit taking everything out in close proximity to the system. Would recommend replacement of heat kit, transformer, wiring harness. Heat kit on order will be in 3-5 days - quoted $902 repair for all parts heat kit, transformer, and wiring. Returned with parts discovered heat kit delivered was not right heat kit for this system. Will call with availability of new heat kit.
Penrose, NC 28766
Cameron S.
Chang d electric heat strip out and breaker and checked system operation - everything looks and runs great!
Penrose, NC 28766
Jay E.
Found damper number 22 bedroom area not opening when 24 V is removed. I replaced this damper and checked it several times to make sure it opened and closed zone three actuator was replaced because it was getting hung up on opening as well. Tested zone three open and closed like it’s supposed to. These two are under warranty. When I turn the breaker that’s on the unit back on it would not power back up on closer inspection I found condensation on it and we will have to replace either the breaker or the heat strip. This will also be under warranty. Right now I have the wires wire nut together so if if we need to turn the power off. We have to turn it off at the main breaker
Penrose, NC 28766
Cameron S.
Performed AC cooling tune up on Bosch heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drains for both air handler and dehumidifier, treatment of condensate pump. Everything looks and runs great! Unit air filter is changed.
Penrose, NC 28766
Kelsey T.
The condensation around the outdoor unit was from a small section on 3/4 lineset that was not insulated. Added insulation and went over everything with homeowner.
Penrose, NC 28766
Jay E.
AHRI# 207658522 20 SEER2; 13 EER2; 9.5 HSPF2 MAKE: Bosch MODEL: BOVB36HDN1M20G Heat Pump BVA24WN1M20 Air Handler 8 KW Electric heat kit Tech Pure TTMAC 2122 Merv 11 media filter Installation shall include: Equipment specified above plus materials and labor to include: • Necessary Electrical for Installation. • Permit Fee for Installation • Bosch Manufacture’s Warranty: Ten (10) Year Limited Parts including Compressor. • One (1) year labor warranty provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central Inc Workmanship.
Penrose, NC 28766
Cameron S.
Performed AC maintenance tune up service for heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain line. Changed filter today 6/10/24 customer provided filter.
Penrose, NC 28766
Review
Cameron S.
Performed AC maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor unit, treatment of drains. Everything looks and runs great! Filters 14x25x1
Penrose, NC 28766
Cameron S.
No cool main unit - found system capacitor flat - system attempting to start - replaced capacitor - cycled system to check operation - performed AC maintenance tune up on Heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor units and treatment of drain lines and condensate pump. Everything looks and runs great!
Penrose, NC 28766
Cameron S.
Performed AC maintenance tune up service on 2 heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, shut down, cleaning of indoor and outdoor coils, treatment of drain lines. Everything looks and runs great!
Penrose, NC 28766
Jay E.
Was informed heat strips didn’t work. Turned on emergency heat at thermostat. Tested amp draw on both 5KW sections both drawing 20 A switched it off at the thermostat several times and retested with the same results. Took a temperature difference on the heat strips 20°. Tested heat pump and auxiliary heat at the same time. Auxiliary heat doesn’t come out with the heat pump with a 10° setpoint. Thermostat should be turning on the auxiliary heat at 2° below set point or more this thermostat needs to be replaced
Penrose, NC 28766
Jay E.
Replaced 3/4- 3/8 lineset, and filter dryer. Added 9lbs of refrigerant. Tested system operation. System is now working properly.
Penrose, NC 28766
Cameron S.
Charged with a bit of r410 about a pound and a half. Turned on breaker to outdoor unit was connected to a junction box that lead to outdoor shed which was turned off.
Penrose, NC 28766
Cameron S.
Found heat pump system lineset is pourous causing refrigerant leak on near side to air handler on 3/4" line. Want to have another tech come by to confirm and quote a repair. Charged system with 2# r410a and cycled to check operation. System is heating at this time. Will return this afternoon to quote a repair for lineset.
Penrose, NC 28766
Kelsey T.
Delta T of 63F with heat kit on, 33F without. Changed filter. Brushed out drain trap. Suction line temp of 170F with an outdoor ambient of 55F. Fastened down screws on condenser and wedged condenser lid to remove rattling noise when unit is running. Checked blower wheel and EVAP coil, no sign of blockages or damage. Capacitor functional. System is functioning normally. Homeowner did not receive their summer tune up. Honoring their membership.
Penrose, NC 28766
Cameron S.
Performed evaporator coil change out and electric heater kit change out. Performed triple evaluation and charged according to manufacturers specifications. Cycled system to check operation of both heat kit and heat pump. Everything looks and runs great!
Penrose, NC 28766
Review
Kelsey T.
Delta T of 28F. Filter changed. Brushed out drain trap and condensate pump. Checked blower wheel and coils for dust and damage. Suction line temp of 119F with an outdoor ambient of 38F. No errors codes on inverter board. Electric heat kit working as intended. System is functioning normally.
Penrose, NC 28766
Kelsey T.
Dual Fuel system at 10 CO ppm and 12% O2. Made slight gas valve adjustment to bring O2 down. Gas valve falls to 0 ppm on shutdown. Checked charge in cooling mode. Burners are clear. Inducer sounds good. No over amping from system. HP system had a dirty filter. 18.4 F delta T in cooling mode after removal of dirty filter. Checked all capacitors, amp draws, and voltages. Systems are functioning normally.
Penrose, NC 28766