Cameron  S.
Cameron S. Checked in
Ran system in both heating and cooling operation, found system operates normally in both heat pump and furnace as well as in cooling operation. Found upstairs thermostat settings different from main floor stat. Changes upstairs thermostat to match downstairs thermostat settings. Adjusted balance point on thermostats and zone control panel to all match the same temperature. Tested outdoor temperature sensor, found accurate within a tenth of a degree. Checked system start up, operation, shut down, defrost. Everything looks and runs great! No additional changes required at this time.
Weaverville, NC 28787
Review
Cameron was very thorough in his service. At the end he recapped all that he had done and gave me some tips on what I could do to maintain the system in between checkups.
Raymond - Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Found leak caused by humidifier o rings not sealing base of steam canister when humidifier heats up. Starts off as a slow drip and continues to build as the water bypasses o ring. Replaced steam canister and o ring kit with customer provided canister kit. Cycled system to check operation. Did not note any other leaks on system at this time. Covered as part of tune up. Everything else looks and runs great!
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Performed ultimate heating tune up on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shut down, defrost, electric resistance heat. Everything looks and runs great!
Weaverville, NC 28787
Jay E.
Jay E. Checked in
Was informed that in the morning thermostat was on 70° hold house was 68° found the outdoor sensors connected to the zone board which was set to lock out the furnace at 35°. It’s possible that the heat pump is not enough to heat this house Above 68° when it’s below 40° outside we readjusted the furnace lockout to 40° tested the furnace tested the heat pump. Also, second issue could possibly be the registers that is not blowing the air to the ground. Very high ceiling in main room. Bedrooms also have the cheaper type of register. With ceiling returns any warm air that comes out of the register, heads up to the ceiling and get sucked out of the return before the room gets warm if changing the differential on the system doesn’t make a difference I recommend the registers be changed out.
Weaverville, NC 28787
Review
Our heat quit working and it is only a few years old. I called Comfort Central and they were able to get someone out within 24 hours. Jay had the necessary parts and components on his van and had the system running within a short period of time. I was pleased that the cost was reasonable as well.
Bob - Weaverville, NC 28787
Jay E.
Jay E. Checked in
Tested outdoor temperature 1300 ohms correlates to the same outdoor temperature after I reconnected the wires from the sensor to the thermostat wire. The system came on after a time delay. It’s possible that it was a bad connection on one of the wire nuts.
Weaverville, NC 28787
Jay E.
Jay E. Checked in
Thermostat was running program instead of permit hold. Reset schedule so each time change is 75 degrees Tstat needs to be in heat and hold.
Weaverville, NC 28787
Jay E.
Jay E. Checked in
Found wire common that came off the blower. Had fallen off the board. Adjusted spade clip. Reconnected tested blower. Tested operation of steam. Humidifier to make sure it comes on and shuts off. Everything seems like it’s working well.
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
System satisfied on arrival. 70 F inside home. Turned temperature up one degree and the furnace came on. No errors or warnings on T stat. Walked outside to condenser and cupped hands around OT sensor to see if it's in Low Temperature lockout. It was, and the system came on after just a few minutes. Went in side to adjust balance point but didn't see an option on the T stat. Adjusted backup heat droop from comfort to 2. It has been below freezing since last night and in the 20s all morning. System is just locking out the compressor like it's supposed to do when below freezing. If the system is going into back up heat when in the 40s there may be a balance issue, but with current temps it appears to be doing what the dual fuel system was designed for.
Weaverville, NC 28787
Jay E.
Jay E. Checked in
SEER2 14.5; HSPF2 7.8; EER2 12 Make: Goodman Model: GSZB403010 Outdoor Unit AMST4030BU14 Air Handler 8 KW Electric Heat Honeywell T-6 Wifi thermostat Tech Pure Merv 11 Media Filter Installation shall include: Equipment specified above plus materials and labor to include: • Electrical is included. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Goodman Manufacturer’s Warranty: Ten (10) Year Limited Parts, including Compressor. • Honeywell warranty: five (5) years parts. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
Replaced 1st stage capacitor. Still threw sparks at me from the common wire after the electrician gave the all clear. System throwing outdoor ambient temp code. Held sensor in hand to warm it up, system came on.
Weaverville, NC 28787
Review
We’ve used Comfort Central for several years and have always been satisfied with their service. This year our 20 year old furnace started malfunctioning just when the weather turned cold. They were able to find and order a replacement part and get it repaired within a couple of days. As soon as it was available they had a technician here and it was fully functional
Bob - Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
Replaced control board in furnace. No longer throwing pressure switch fault code. Burners coming on cleanly.
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
Basement furnace has slight noise from age of unit, but nothing to be caused for concern. Typical operating noise. Furnace door is missing a peg, so possible noise is coming from the door occasionally rattling. Ran the system with and without filter. Ran system with door on and off. No over amping from inducer motor or blower motor. Blower wheel is clean. Inducer does not have water backed up; no paddling. Gas valve, pressure switches, burners all operating normally.
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
Needs board. Calling him when board comes in to Ferguson.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Performed dual fuel maintenance tune up checking all electrical components, refrigerant balance, performed full combustion analysis on furnace, cleaned burners, flame sensor, checked gas pressure, cleaned drain lines, cycled system checking start up, operation, shut down, defrost. 3 flash error code caused by furnace draining slow, after cleaning of drain lines and condensate box for furnace fault did not occur again. Everything looks and runs great! No additional recommended changes at this time.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Installation of iwave r and deep clean of evaporator coil. Recommended running fan in the on position.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Response and diagnostic to check a leak in attic - did not identify any leaks from the attic unit at this time system drain is streaming water and draining effectively and normally to the outside. Insulated drain trap. Attached photo of leak to track development of stain over time.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Replacement of Evaporator Coil out of Manufacturer's Parts Warranty Charged to manufacturers specifications Performed preventative maintenance tune ups. Everything looks and runs great!
Weaverville, NC 28787
Review
Andrew was awesome
Bradley - Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
System had two separate caps rigged together for 45 mfd. One cap died. Replaced both caps with the appropriate size cap for the system.
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
Upstairs delta of 17, filter changed, drain line blown out, SC 16 SH 4. Downstairs delta of 19, filter changed, drain line blown out, SC 14 SH 15. Cleaned lawn clippings off both condensers and treated coils with green coil cleaner. Systems are cooling normally.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Found unit was low about 3 Oz of refrigerant believe loss of refrigerant was caused by removal of gauges from last visit. After adding refrigerant and cycling system everything is operating within manufacturers specifications. No additional recommended changes at this time.
Weaverville, NC 28787
Cameron  S.
Cameron S. Checked in
Found system filter plugged causing low airflow across evaporator coil. After removing filter system cycles and operates normally indicating system air filter is the culprit for system freezing up. Recommend replacing filter. Can find filters at filterfetch.com using product code: CKT-P4NY
Weaverville, NC 28787
Kelsey T.
Kelsey T. Checked in
AMERICAN STANDARD HEAT PUMP - Drain line clogged. Clipped drain line, blew out with CO2 canister, reassembled line with coupling. Tested drain line with water after reassembly.
Weaverville, NC 28787
Jay E.
Jay E. Checked in
Ultimate ac Tune-Up Heat Pump: serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and refrigerant to manufacturer specifications. Cleaned trap and all coils. Tested temps. No issues found Replaced battery’s on upstairs thermostat
Weaverville, NC 28787
Jay E.
Jay E. Checked in
HVAC and Thermostat Service and Repair - Found thermostat set to emergency heat instead of cool. Explain thermostat and how it works. Carrier doesn’t make a user-friendly thermostat. We took a picture of it printed it out and drew arrows on the picture of what each button does. Tested system found it low on refrigerant. Added refrigerant to manufacture specs. System has a 20° temperature difference ...No other issues found
Weaverville, NC 28787
Kevin S.
Kevin S. Checked in
Board is fried in furnace. Need new board.