Heating & Air Conditioning Services in Fletcher, NC
Call Comfort Central for Outstanding HVAC Service
For exceptional heating, air conditioning and indoor air quality services in Fletcher, NC, call Comfort Central, Inc. Our professional, extensively trained HVAC service technicians have all the knowledge and experience necessary to ensure your home is kept comfortable throughout the entire year.
For exceptional heating, air conditioning and indoor air quality services in Fletcher, NC, call Comfort Central, Inc. Our professional, extensively trained HVAC service technicians have all the knowledge and experience necessary to ensure your home is kept comfortable throughout the entire year.
To schedule an air conditioning or heating service in Fletcher, NC today, call Comfort Central, Inc. at 828-483-4040 or request an estimate online.
Local Reviews
for Fletcher, NC
Our Reviews by City
Excellent service
Ann - Fletcher, NC 28732
Cam was great as usual. I have been a customer with Comfort Central about from the beginning. Over the years they have installed heating and cooling systems in each home every time I have moved. I have always been very happy with their service, workmanship and products.
FletcherNC28732 35.44-82.4975Excellent Work & Professionalism
Maureen - Fletcher, NC 28732
The Comfort Central technicians were very courteous and professional. The details of the job were clearly explained, and the pricing was very reasonable. I'm impressed with this company and would highly recommend.
FletcherNC28732 35.435-82.46Cameron S.
Performed heating tune up on heat pump system checking all system components including, electrical, refrigerant balance, electric resistance heat, system start up, operation, shut down, defrost. Everything on system looks and runs great! Would like to quote taking bathroom duct and extending it to the SW bedroom of home ~15' - 20' and changing current duct in that bedroom from a 6" to an 8" also ~15'
Jay E.
Found low voltage fuse blown. Tested operation to see if there is a short. System shut done again do to a low voltage short. Found short inside outdoor unit on pressure switch. Repaired wire made sure no other wires were gonna have a rubout and short closed. Everything up tested it again for operation.
Cameron S.
Found burned fuse on blower board - replaced fuse - repaired connection on common wire at outdoor unit. Cycled unit to check operation. Everything looks and runs great!
Cameron S.
CC Renewal
Cameron S.
Performed heating maintenance tune up on heat pump system checking all electrical components, refrigerant balance, defrost, unit start up, operation ,shut down, back up resistance heat operation, cleaning of drain trap, treatment of drain pan, everything looks and runs great! No recommended changes at this time.
Cameron S.
Performed ultimate heating tune ups on both furnace systems performing a full combustion analysis. Cleaning of burners and sensors, cycling of safeties, flushing of drains, checking start up, operation, shut down, checked all electrical components. Everything looks and runs great! No recommended changes at this time.
Cameron S.
Performed ultimate heating tune up for gas furnace system. Performed full combustion analysis, checked all electrical components, flushed and treated drain lines, cleaned burners, flame sensor, checked start up, operation, shutdown.
Kelsey T.
CO at 18 ppm. O2 9%. Checked refrigerant levels in straight cool AC; homeowner mentioned system leaked previously. Burners are clean. Gas valve is good with no sign of leaks. Wall filter changed by homeowner. Checked amps, caps, volts, temps, and pressures. Blower has some dust, but no blockages that would require cleaning. System lights off cleanly with a good flame. Inducer also working as intended. System is functioning normally.
Jay E.
Replaced condenser fan motor tested operation of system and air-conditioning no other issues found today
Cameron S.
Found system low on charge.Performed a leak search and added refrigerant to manufacture specs. Play service caps with brass caps with o-rings. Couldn’t find leak
Kevin S.
Condenser capacitor failing upon arrival. Tested cap. 20 mfd on a 30 + 5. Replaced capacitor. System functioning normally.
Jay E.
Go on refrigerant performed leak search and added refrigerant to manufacture specs. Replaced service port caps. Old ones had no o rings. Couldn’t find the leak. Everything else seems to be running well on this spring tuneup
Cameron S.
Performed cooling tune up on AC system checking system operation, refrigerant balance, electrical components, cleaning of indoor evaporator coil and drain line and outdoor condensing coil. Everything looks and runs great!
Cameron S.
Performed cooling tune up everything looks and runs great!
Jay E.
Tuneup on a ICP carrier air conditioner.
Brian J.
Warranty electric heating repair